Invincible II lockers are designed for heavy duty use in the storage of athletic gear, or wherever a high degree of ventilation is required. The doors and sides are perforated with a diamond-shaped pattern for the free flow of air. For extra durability, the doors are made from 14 gauge steel, and the sides, tops, bottoms and shelves are 16 gauge steel. Backs are 18 gauge. Stainless steel recessed handles are standard on 1, 2 and 3 tier models. Special nylon glides fastened to the latch channel assembly help to maintain noise.

 

Invincible II lockers come in a variety of styles: single tier, double tier, and 3 tier all have as standard the Classic III stainless steel recessed handle.

 

Standard 4, 5, 6, 8 and 9 tier box locker doors have a padlock hasp and a friction catch, and will accept built-in locks. Available at extra cost is a spring loaded positive catch that also accepts padlocks or built-in locks.

Both double tier and 3 tier lockers have horizontal frame members welded between the doors for added strength and security. If slope tops are required, use hoods. Group Ends must be ordered to and each row; see your representative for details.

Invincible II Defiant II

The Defiant II Single Point Latch option for Invincible II 1, 2 & 3 tier lockers offers excellent security and the low maintenance inherent in a door with no moving parts. It is available with diamond shaped perforations or as a solid door. Each has a patented deep drawn stainless steel pocket handle with an integral door pull. All Defiant doors have continous hinges.

 

Penco Invincible II ™ Locker Specifications

MATERIALS:

SHEET STEEL:  All parts made from prime grade mild cold rolled sheet steel free from surface imperfection, and capable of taking a high grade enamel finish.

HINGES:  .074" thick, 2" high, double spun, full loop, tight pin, five-knuckle hinges, projection welded to door frame and securely fastened to the door with 2 steel rivets.  Doors over 48" high shall have three hinges, all other doors shall have two hinges except the 24" wide x 60" or 72" doors which shall have four hinges. 

FINISHING:  Chemically pretreat metal with a six stage cleaning phosphatizing and metal preparation process. Finish coat shall be electrostatically applied powder coat enamel properly cured to paint manufacturer specifications to achieve optimum performance. All lockers shall be painted inside and outside with the same color.

EQUIPMENT:  Coat hooks and coat rods are zinc plated.  Truss fin head bolts and hex nuts are zinc plated.

FABRICATION GENERAL:

CONSTRUCTION:  Built on the unit principle - each locker shall have an individual door and frame, individual top, bottom, back and shelves with common intermediate uprights separating compartments.  Lockers shall be fabricated square, rigid and without warp.  Doors shall be flat and free of distortion.

DOOR FRAME:  All door frame members to be not less than 16 gauge formed to a channel shape.  Vertical members to have an additional flange to provide a continuous door strike.  Intermembering parts to be mortised and tenoned and electrically welded together in a rigid assembly capable of resisting strains.

Cross frame members of 16 gauge channel shapes including intermediate cross frame on double and triple tier lockers shall be securely welded to vertical framing members to ensure rigidity.

BODY:  Bolt spacing in locker body construction not to exceed 9" o.c.  All locker body components shall be made of cold rolled steel specially formed for added strength and rigidity and to ensure tight joints at fastening points.  Tops & bottoms shall have three sides formed 90o and the front offset formed to be flush with the horizontal frame member.  Shelves shall have sides formed to 90o, the front edge shall have a second bend.  Backs shall be 18 gauge; all other body parts shall be 16 gauge.

DOORS:  Doors 20" or higher shall be formed from one piece 14 gauge cold rolled sheet steel.  Formations shall consist of a full channel shape on the lock side of adequate depth to fully conceal the lock bar, channel formation on the hinge side, and right angle formations across the top and bottom.  Doors over 15" wide and over 30" high shall have a 3" wide full height 20 gauge reinforcing pan welded to the inside face of the door on 6" centers.

Doors for box lockers 4, 5, 6, 8 & 9 tiers high shall be 14 gauge steel and have channel formations on lock side and hinge side and have right angle flanges on the top and bottom.

DOOR HANDLE & LATCHING 1, 2 & 3 TIER:  Handles shall be recessed in the door and be finger lift control.  The 20 gauge drawn pocket shall be brushed stainless steel securely fastened to the door with two tabs plus a positive tamper resistant decorative fastener.  The pocket shall be of sufficient depth to prevent a combination padlock, built-in combination lock or key lock from protruding beyond the face of the door.  A lock hole cover plate shall be provided for use with padlocks.

The lifting piece shall be 14 gauge formed steel, attached to the latching channel with one concealed retaining lug and one rivet assuring a positive two point connection.  Handle finger lift shall have a padlock eye for use with a 9/32" diameter padlock shackle.  It shall have a sound deadening molded comfortable finger lift.   

Doors to have latch clip engaging the door frame at three points on 60" & 72" high and two points on 20" through 36" high doors.  Locking device to be positive, automatic type, whereby locker door may be locked when open, then closed without unlocking.  One rubber silencer shall be firmly secured in the frame at each heavy gauge latch hook.  Latch clips shall be glass filled nylon for long life and low friction and shall hold doors shut by engaging the latch hooks.  Latch hooks on diamond-perforated lockers shall have tamper guards.  The latch channel assembly shall be quieted by the use of unique nylon glides to reduce noise.

DOOR HANDLE & LATCHING 4 TO 9 TIER BOX LOCKERS:  Doors shall be punched for use with padlocks or built-in locks.  Doors for use with padlocks shall be equipped with an 18 gauge combination door pull, staple and lock hole cover plate with integral friction catch. 

VENTILATION:  All locker sides and doors 20" or higher shall be perforated with diamond-shaped openings 3/4" wide x 1-1/2" high in a quantity and pattern to insure maximum ventilation and maintain structural strength.  All other doors shall have small diamond-shaped perforations 7/16" wide x 15/16" high.

NUMBER PLATES:  Each locker to be supplied with a polished aluminum number plate, 2-1/4" wide x 1" high, with black numerals not less than 3/8" high.  Number plates shall be attached to the face of the door with two aluminum rivets.

INTERIOR EQUIPMENT:  Single-tier lockers 48-1/2" or higher shall have a hat shelf located approximately 9" below the top of locker; if less than 18" deep, locker shall have three single-prong hooks and one double-prong ceiling hook.  Single Tier lockers 18" deep or more shall have a coat rod instead of a ceiling hook.  30" & 36" high lockers shall have three single-prong wall hooks and one double-prong ceiling hook.  Hooks to be steel, ball tip zinc plated, attached with two bolts per hook.  20" & 24" high lockers to have three wall hooks.

LOCKER ACCESSORIES:  Lockers shall be furnished with the accessories selected from the Accessory Specifications.

 

OPTIONS:

BODY:  Lockers shall be assembled using rivets.

DOORS:  Box locker doors 4 to 9 tier, as an alternative option each door shall be furnished with a stainless steel padlock strike. 

DOOR HANDLE & LATCHING 4 TO 9 TIER BOX LOCKERS:  As an alternate option, each door shall be provided with a finger operated 11 gauge slam latch with an electrogalvanized trigger, and a spring contained in a 14 gauge case welded to the door.  The spring latch engages a 13 gauge hasp welded to the frame.  Rubber bumpers shall be securely installed in the frame.

DOOR VENTILATION:  Standard louvers or mini louvers (5/8" wide x 1/4" high) may be substituted for diamond perforations in doors.  All louvers and perforations shall be placed in doors according to manufacturer's standard pattern.

ADA COMPLIANT LOCKERS:  Handicap lockers shall have recessed handles and shall be single tier or the lower opening of a double tier locker.  Locker bottom shall be a minimum of 9" off the floor, or an extra shelf placed 9" off the floor.  Single tier lockers shall have a shelf 48" off the floor.  Doors assigned for handicapped use shall have an appropriate symbol sign.

 

EXECUTION:

INSTALLATION:  Install metal lockers at location shown in accordance with manufacturers instructions for plumb, level, and flush installation.

ANCHOR LOCKERS to the floor and wall 36" on center or less as recommended by the manufacturer.

INSTALL SLOPING HOODS AND METAL FILLERS using concealed fasteners.  Provide flush hairline joints against adjacent surfaces.

INSTALL BENCHES by fastening bench tops to pedestals and securely anchoring to the floor using appropriate anchors for the floor material.

ADJUST & CLEAN:  Adjust doors and latches to operate without binding.  Verify that latches are operating satisfactorily.

TOUCH UP marred finishes with factory supplied paint.

 

 

INVINCIBLE II DEFIANT II SINGLE POINT LATCH SPECIFICATIONS

  

When specifying Invincible II Lockers with Defiant II Single Point Latch (SPL) doors, substitute the following specifications for "Doors," "Hinges" and "Door Handle & Latching, 1, 2 & 3 Tier" to the Invincible II specification above

. Delete "Door Handle & Latching 4 to 9 tier Box Lockers."

DOORS:  All doors shall be formed from 14 gauge steel. Formations shall be channel shape on the hinge and latch sides, and right angle formations across the top and bottom. Top and bottom flanges shall have one 90 degree bend. The latch side formation shall include a slot to fully engage an additional anti-pry lug integral with the padlock hasp limiting motion in any direction. On doors measuring 12" through 18" wide, additional reinforcement shall be in the form of a vertical 18 gauge pan measuring 3-1/2" wide, MIG-welded to the top and bottom flanges and hinge side channel, with an additional ½" flange spot welded a maximum of 8" on center to the door skin to maximize door rigidity. Doors measuring more than 18" wide shall be reinforced using a 20 gauge horizontal box pan MIG-welded a maximum of 8" on center to the hinge and latch side channels, and spot welded a maximum of 8” on center to the door skin along the upper and lower pan edge for optimum strength, quiet operation and stiffness. Door shall be manufactured to allow ventilation and stiffness.

HINGES: 16 gauge continuous hinges (full length of the door) are welded to the door and riveted to the frame. 

DOOR HANDLE & LATCHING 1, 2 & 3 TIER:  Handles shall be recessed in the door. The formed pocket shall be brushed stainless steel securely fastened to the door with two lugs plus a positive tamper resistant fastener. The pocket shall be of sufficient depth to prevent a combination padlock, built-in combination lock or key lock from protruding beyond the face of the door. An anti-pry lock alignment bracket shall be supplied for use with built-in combination locks to facilitate installation, adjustment and to increase resistance to prying by mechanically engaging the hasp assembly. A lock hole cover plate shall be provided for use with padlocks. All pockets shall be 22 gauge drawn stainless steel for superior strength. Door pull shall be formed in the pocket. Pocket and pull shall be integral.

Doors shall have a catch to retain unlocked doors in the closed position. Locking shall be accomplished by an 11 gauge lug welded to the locker frame. The lug shall include a surface for the bolt of a built-in combination or key lock to engage. A padlock staple shall protrude through the 22 gauge pocket. The hasp assembly shall include an additional lug that mechanically engages a slot on the latch side door formation preventing the spreading of the door from the frame channel. A separate bracket shall be field installed to brace the lock hasp assembly against the locker side to prevent twisting of the frame. Rubber door silencers shall be firmly attached to the locker frame.

 